Block Occupancy and
Feedback - BOD 20 |
|
 |
The
Block Occupancy Detector BOD-20, is rated at ten-amps and is used to send detection to either our
AIU-01 or most common signal systems from other manufacturers.
With the BOD-20 there is no electrical connection to the track. The track wire is merely
fed through a hole in the BOD-20. Locomotives trigger the detector because they draw
current through the decoder, un-powered rolling stock will require some means such as a
resistor wheel set.
The detector can be used with any booster up to 20 amps capacity. A LED can be added for
simple indication of the status of staging tracks or progress through a helix. The LED
will require a external power supply of 5 to 15 VDC to power the LED.
|
|
Auxiliary Input Unit
AIU-01
|
|
 |
AIU-01 Auxiliary Input Unit Each auxiliary input unit AIU-01, collects up to 14 signals from either the block
occupancy detector, BOD-01, or auxiliary contact's switch machine or other devices and
forwards this information to the command station via the cab bus.
For those hobbyist that purchase Dispatcher, the combination of these two devices
will allow addition flexibility in CTC or automatic operation on the model railroad.
|
|
Stationary Decoder Switch It |
|
 |
The
Switch-it is the economical Stationary Decoder for Tortoise or Switchmaster Slow Motion
Switch Machines. Each decoder come with two outputs and supports a full range of DCC
addresses [1-2044]
Each machine can have a independent address and has connections for "local"
control push buttons.
Size 54 mm x
33 mm [2.1" x 1.3"]
|
|
Stationary Decoder Snap-It |
 |
The NCE Snap-It stationary decoder
will operate a single snap action turnout motor, and is specifically
designed for low current motors such as Atlas, Lifelike, Bachmann, etc.,
but it will operate high current machines such as the Rix & Peco with a
additional capacitors ad or the use of an external power supply.
The Snap-It supports address ranges
from 1 to 2044 and is programmed on the main. Pushbutton inputs are
provided for manual switch operation.
The new version 3 snap
has been tested and found to operate the Peco point motor and accessory
switch when installed with the Peco snap action turnout.
Size 46 mm x 38 mm [1.80" x 1.50"]
|
|
Stationary Decoder Switch-8 |
|
 |
Stationary decoder for 8
Tortoise Switch Machines.
Simple hook up just 2 wires
to the power bus and two wires to each slow motion motor. Easy addressing,
no need to connect to a programming track with each output being able to
have its own separate address, maximum flexibility.
Switch-8 remembers settings
even during power outages. Support full range of DCC accessory addresses
[1 - 2004]
|
|
Universal Throttle Panel
Assembly - UPT |
|
 |
The UTP cab bus panel provides a low cost means of adding walk
around capability to your layout. The panel has 4 RJ-12 connectors wired in parallel, two
on the front and two on the rear.
Your cab bus can be "daisy chained" from one panel to the next using the rear
connectors. One or two cabs can then be plugged in to the front connectors. A 12v DC plug
is provided at the rear to allow external power to the Cab bus to be added for runs over
60' [20 meters]
|
|
DIN - Universal Throttle
Panel Assembly |

|
Recommended
for heavy duty club usage and low cost Your cab bus can be "daisy chained"
from one panel to the next using the rear connectors.
One or two cabs can then be plugged in to the front connectors. A 12v DC plug is provided
at the rear to allow external power to the Cab bus to be added for runs over 60' [20
meters]
Can also with Lenz X PressNet TM
|
|
NCE Bus Clock |
|
 |
The NCE Clock simply plugs into and NCE Cab Bus to display the current scale time
held in the command station.
Great for yards were the shunters need to know the current scale time but are running with
the intermediate or basic cab.
|
|
Circuit Breaker EB 3 |
|
 |
The EB3 allows a existing single booster to
be split into 3 separate output, not more complete layout shutdowns in the
event of a short circuit.
The EBs features selectable 2,3 & 4 amp outputs
for each district. Easy hook up using a screwdriver with LED status
outputs. Additional opto isolated circuits are to provided to feed signal
circuits or control panel indicators. Short circuit response time and
power up times are provided to accommodate start up of sound decoder
equipped locomotives.
EB3 will not operate with the System One
boosters.
|
|
Decoder Tester |
|
 |
Finally a affordable Decoder Tester.
Quickly determine if a fault existing in a decoder before or after
installation. Test all types of decoders and 4 function outputs. Separate
motor terminal provided.
Fully check your decoders before installation, save time and effort.
|
|
Auto SW Switch Panel |
|
 |
Auto SW - Disconnects mainline when in
programming mode.
When the PowerCab is in "USE PROGRAM TRACK" you can end up
programming all your locomotives. The Auto SW will automatically
disconnects the mainline and activate a separate programming track
preventing programming command being sent to the main line.
Works with other DCC systems such as Digitrax
Empire Builder, Big Boy or Challenger.
|
|
CP 6 Circuit Protector |
|
 |
Circuit protection for up to 6 sections of
your railroad. Operates with ANY DCC system. Factory set to 1 Amp per
section. Sections can be connected together for more power per section.
Optional lamp packs for 1.75 Amps per section also available, refer
price list.
|
|
Plug Panel Power Cab |
 |
Add a separate PCP panel to operate your
Power Cab in other places or on other layouts, with a separate Trans 02 and you will
only to move the Power Cab from test bench to layout.
|
|
Macro Panel |
|
 |
Mini Panel - While we were finishing the
Macro Panel, the Mini Panel was invented. It will be a simpler device
(macros and accessories only).
Full details to be advised on release
|
|
SIG-12 Signal Controller |
|
 |
- Works with Double Gapped or Common Rail
Layouts.
- Can an operate ANY signals on the market
[searchlight,2/3 light/position light, etc.]
- Up to 32 different aspects
- Each SIG 12 operate 2 signal heads
- Simple signals to FULL prototype with
interlocking
- Automatic operations can be overridden by
computer or CTC panel
Full details to be advised on release
|
 |
Add this USB computer interface for computer
programming and/or operation of your Power Cab equipped layout. Requires
USB cable, computer and railroad computer program such as JMRI Decoder Pro
and Panel Pro
|
|
|
|
|
|
|