The MRC has many customers that are using the NCE decoders with their Lenz Systems.

We have received reports of the latest Lenz Ver 3.5 software have reported a error 02 when trying to program the NCE decoders. The problem is in the current Lenz software and should be reported.

NCE has advises us that you should use paged mode for programming if this problem arises. This should provide more reliable results. Additionally were long address are required directly programming CV17/18 and CV29 in another method that can be examined. The best explanation of programming these CV can be found on the Sound traxx Web Site for their DSD-150 sound decoder

From Lenz regard the Lenz Compact System and programming NCE decoders

Please write a 1 in register 6.
Write the new address into register 1.
Please do this direct without reading the registers.

Best regards Thorsten Gradl